{"title":"I2 zone in Coldstream: General Industrial Zone","code":"I2","slug":"i2","name":"General Industrial Zone","group":"Industrial","section":"702","site_specific_zone":false,"summary":"Accommodate a broader range of industrial uses on a large lot or parcel.","fields":{"purpose":{"value":"Accommodate a broader range of industrial uses on a large lot or parcel.","quotes":["702.1 The intent of the General Industrial Zone is to accommodate a broader range of industrial uses on"]},"primary_uses":{"value":["Agriculture (on lands within the ALR)","Agriculture, Intensive (on lands within the ALR)","Automobile Repair and Sales","Automotive Wrecking and Salvaging","Bulk Landscape Supplies","Commercial Motor Vehicle Repair and Sales","Data Centre","Farm Equipment Repair and Sales","Heavy Equipment and Machinery","Manufacturing","Recreation Vehicle Repair and Sales","Recycling Depot","Transportation and Logistics","Warehouse"],"quotes":["(a) Agriculture (on lands within the ALR)","(b) Agriculture, Intensive (on lands within the ALR)","(c) Automobile Repair and Sales","(d) Automotive Wrecking and Salvaging","(e) Bulk Landscape Supplies","(f) Commercial Motor Vehicle Repair and Sales","(g) Data Centre (*2)","(h) Farm Equipment Repair and Sales","(i) Heavy Equipment and Machinery","(j) Manufacturing","(k) Recreation Vehicle Repair and Sales","(l) Recycling Depot","(m) Transportation and Logistics","(n) Warehouse"]},"secondary_uses":{"value":["Accessory Buildings and Structures","Single-Detached Dwelling with Secondary Suite or Manufactured Home"],"quotes":["(a) Accessory Buildings and Structures","(b) Single-Detached Dwelling with Secondary Suite or Manufactured Home"]},"min_parcel_area":{"value":"0.4 ha (community water and sewer); 2 ha (community water and onsite sewage)","quotes":["(a) 0.4 ha – Lots serviced by Community Water and","(b) 2 ha – Lots serviced by Community Water and Onsite"]},"min_parcel_width":{"value":"30 m","quotes":["(2) Lot Frontage (a) 30 m"]},"max_parcel_coverage":{"value":"55% for all buildings and structures; 15% for impervious hard-surfaced areas","quotes":["(a) 55% for all Buildings and Structures; and","(b) 15% for impervious hard-surfaced areas"]},"max_density":{"value":"1 dwelling unit (a Single-Detached Dwelling or a Manufactured Home); a Secondary Suite only if the lot is in the ALR and over 1 ha","quotes":["(a) 1 Dwelling Unit","(b) a Secondary Suite use is permitted within a Single-","is greater than 1 ha"]},"max_height":{"value":"18 m","quotes":["(7) Principal Building (a) 18 m"]},"max_height_accessory":{"value":"11 m; Single-Detached Dwelling 11 m or 3 storeys","quotes":["(8) Accessory Building (a) 11 m","(b) Single-Detached Dwelling – 11 m or 3 storeys; and"]},"setback_front":{"value":"15 m from ALR; 9 m from a road or Controlled-Access Highway fronting a Residential Zone; 6 m for all other zones","quotes":["(a) 15 m from ALR","(b) 9 m from a Road or Controlled-Access Highway fronting a","(c) 6 m for all other Zones"]},"setback_rear":{"value":"15 m from ALR (may require 8 m landscape buffer); 9 m from a Residential Zone; 6 m from all other zones","quotes":["(2) Rear Lot Line (a) 15 m from ALR (may require 8 m landscape buffer – see","(b) 9 m from a Residential Zone","(c) 6 m from all other Zones"]},"setback_side_interior":{"value":"15 m from ALR (may require 8 m landscape buffer); 9 m from a Residential Zone; 6 m from all other zones","quotes":["(3) Interior Lot Line (a) 15 m from ALR (may require 8 m landscape buffer – see","(b) 9 m from a Residential Zone","(c) 6 m from all other Zones"]},"setback_side_exterior":{"value":"15 m from ALR; 9 m from a road or Controlled-Access Highway fronting a Residential Zone; 6 m from all other zones","note":"Where more than one setback applies, the greater applies.","quotes":["(4) Exterior Lot Line (a) 15 m from ALR","(b) 9 m from a Road or Controlled-Access Highway fronting a","(c) 6 m from all other Zones","Where there is more than one applicable setback, the greater minimum setback shall apply."]},"other":{"value":["Minimum lot depth 60 m; pan-handle lots not permitted","9 m setback where a lot line abuts listed major roads (Aberdeen, Kalamalka, Ricardo, School, Warren and others)","Storage of goods, materials and equipment not permitted in the front yard setback","A dwelling must be at least 7.5 m from a permitted industrial use on the lot"],"quotes":["(a) 60 m (*2)","(c) Pan-handle Lot – Not Permitted","(a) 9 m, where the any Lot Line abuts:","vii. Ricardo Road","Storage of goods, materials, and equipment is not permitted within a front yard setback","minimum of 7.5 m from a permitted industrial use on the lot."]}},"bylaw":{"title":"Zoning Bylaw No. 1838, 2024 (consolidated for convenience, includes amendments adopted up to June 8, 2026)","url":"https://coldstream.civicweb.net/document/104562","accessed":"2026-11-07","note":"The District marks the consolidation \"for convenience only\". The zones are in Schedule A (the url above); the cover and enacting bylaw are at http://coldstream.civicweb.net/Documents/DocumentDisplay.aspx?Id=56951 and the zoning map is Schedule B."},"source_url":"https://coldstream.civicweb.net/document/104562#page=150","place":{"path":"ca/bc/coldstream","name":"Coldstream","region":{"code":"bc","name":"British Columbia"},"country":{"code":"ca","name":"Canada"}},"urls":{"html":"https://govhandbook.com/ca/bc/coldstream/zoning/i2/","markdown":"https://govhandbook.com/ca/bc/coldstream/zoning/i2.md","json":"https://govhandbook.com/ca/bc/coldstream/zoning/i2.json","index":"https://govhandbook.com/ca/bc/coldstream/zoning/index.json"}}