title: "RS-3 zone in Coquitlam: One-Family Residential"
place: Coquitlam, British Columbia, Canada
place_path: ca/bc/coquitlam
zone: RS-3
bylaw: Zoning Bylaw No. 3000, 1996 (consolidated with amending bylaws, updated July 27, 2026)
bylaw_read: 2026-11-07
review: draft
canonical: "https://govhandbook.com/ca/bc/coquitlam/zoning/rs-3/"
json: "https://govhandbook.com/ca/bc/coquitlam/zoning/rs-3.json"
---

# RS-3 zone in Coquitlam: One-Family Residential

Low density single family lots with a minimum lot size of 555 m2 and limited accessory uses.

## Zone rules

- **Purpose:** Low density single family lots with a minimum lot size of 555 m2 and limited accessory uses.
- **Main uses:** One-family residential
- **Also allowed (secondary uses):** Boarding, as limited under Section 508(1); Secondary Suite, as limited under Section 2202(2); Accessory residential; Accessory home occupation, as limited under Section 508(3)
- **Minimum lot area:** 555 m2
- **Minimum lot width:** 13.5 metres (minimum lot depth 22.7 metres)
- **Maximum lot coverage:** 45%
- **Maximum density:** 18 units per hectare (secondary suites excluded from the calculation)
- **Maximum height:** 7.3 m; or 11.0 m for roofs with a pitch of 3 in 12 or greater over at least 80% of roof surfaces
- **Maximum height, accessory buildings:** 3.7 m; or 4.6 m for an accessory building with a roof pitch of 4 in 12 or greater over at least 80% of roof surfaces (detached accessory buildings)
- **Front setback:** 7.6 m
- **Rear setback:** 7.6 m
- **Interior side setback:** 1.8 m
- **Street side setback:** 3.8 m
- **Accessory building setbacks:** Detached accessory buildings sited 1.6 m or more from the house: front 7.6 m, rear 1.2 m, interior side 1.2 m, exterior side 3.8 m; attached or closer than 1.6 m: same as house (7.6 m front, 7.6 m rear, 1.8 m interior side, 3.8 m exterior side)
- **Other rules:** Principal building volume is limited by perimeter wall height and area rules based on lot slope (average perimeter wall height 6.1 m to 7.3 m; wall height never more than 8.4 m; perimeter wall area 93 to 110 square metres per face); these do not apply in the highlighted areas of Schedules C and D; Maximum wall length of a detached accessory building is 9.2 metres; Maximum lot size for a public park is 0.8 hectares; No more than one principal building per lot

## Source

- [Zoning Bylaw No. 3000, 1996 (consolidated with amending bylaws, updated July 27, 2026), s. 2204](https://www.coquitlam.ca/DocumentCenter/View/15229/Part-22-Legacy-Zones-PDF--RS-1-RS-3-RS-4-RT-1-RT-3-and-RM-3-to-RM-6-Zones#page=9) (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply. All zones in Coquitlam: https://govhandbook.com/ca/bc/coquitlam/zoning/index.json