GovHandbook

R-7 zone in Cranbrook: Mobile Home and Single Family Residential Zone

Cranbrook, British ColumbiaDraft, not yet reviewedBylaw read 2026-11-07

In short

Mobile Home and Residential Zone: single to four family dwellings and mobile homes.

Zone rules

PurposeMobile Home and Residential Zone: single to four family dwellings and mobile homes.
Main uses
  • Single family dwelling
  • Two family dwelling
  • Three family dwelling
  • Four family dwelling
  • Mobile home
  • Boarding and lodging
  • Rest home for not more than six (6) persons under care
Also allowed (secondary uses)
  • Home based business
  • Secondary Suite
  • Accessory Dwelling Unit
  • Other uses, buildings and structures accessory to a permitted use
Extra uses on specific lotsLot 1, District Lot 30, Kootenay District, Plan 5182: minimum parcel size for subdivision 405 m²
Minimum lot area418.0 m²
Minimum lot widthFront parcel line at least 1.0 m as written in the bylaw (8.5 m in the bulb of a cul-de-sac)
Maximum lot coverage50% of the parcel
Maximum densityUp to 3 dwelling units on parcels 280 m² or less; up to 4 on larger parcels; one principal use per parcel; one secondary suite per primary dwelling unit; one accessory dwelling unit per parcel
Maximum height7.6 m (mobile home or single family dwelling); 9.0 m (two family dwelling); 11.0 m or 3 storeys, whichever is less (three or four family dwelling)
Maximum height, accessory buildings4.5 m; 7.2 m for an accessory building containing an accessory dwelling unit
Front setback4.5 m
Rear setback2.1 m
Interior side setback2.1 m (at no point less than 1.5 m on irregular parcels)
Street side setback4.5 m
Accessory building setbacksfront 4.5 m; rear 1.5 m (0.9 m where no developed rear lane exists); interior side 0.9 m (one side at least 2.7 m on an interior parcel with no developed rear lane); exterior side 4.5 m; at least 1.0 m from a principal building. An accessory dwelling unit building: not in the front yard, rear 1.5 m, interior side 1.5 m, exterior side 4.5 m
Other rules
  • A mobile home must meet or exceed CSA Standard Z-240 and have its running gear removed
  • Bulk fuel or propane may not be stored within 3.0 m of a mobile home door or within a required yard

Source: Zoning Bylaw No. 3977, 2019 (consolidated to Bylaw 4258, adopted September 8, 2026), s. 7.12 (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. The City publishes the bylaw as one PDF per Part (zone text is in Parts 7.03 to 7.32; each zone's source_url is its Part). The consolidation is for convenience purposes only and is not a legal document; the original bylaws prevail. Bylaw 4161, 2024 (June 10, 2024) replaced RS with R-1 and deleted the old R-1, RD, R-2, R-3A and CD-8 sections. The Part 7.01 file on the City's site still lists the old zone names, and the deleted Parts are not posted, so those zones are not listed here. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.

This zone as Markdown · JSON · all Cranbrook zones · Report an error