R zone in Hazelton: Residential
In short
Low density residential for Single Family and Two Family Dwellings
Zone rules
| Purpose | Low density residential for Single Family and Two Family Dwellings |
|---|---|
| Main uses |
|
| Also allowed (secondary uses) |
|
| Minimum lot area | 400 m² (single family dwelling) |
| Maximum lot coverage | 50% of the site including all buildings and structures |
| Maximum height | 9.0 metres (29.5 feet) |
| Maximum height, accessory buildings | Accessory buildings 4.0 metres (13.1 feet); Accessory Dwelling Units 5.8 meters (19.0 feet) |
| Front setback | 7.0 metres (22.9 feet) |
| Rear setback | 4.0 metres (13.1 feet) |
| Interior side setback | 2.0 metres (6.6 feet) from the side property line |
| Accessory building setbacks | Accessory building may be in the rear yard; rear 0.3 metres (1.0 feet) where it abuts a public lane, 1.2 metres (3.9 feet) where rear line abuts another parcel; max floor area 75 m² (807 ft²) |
| Other rules |
|
Source: Zoning Bylaw No. 478, 2015 (unofficial consolidation updated July 19, 2023; includes Bylaws 494, 518, 524, 529), s. 5.1 (read 2026-11-08)
Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. The Village's consolidation is marked "Unofficial Consolidation"; where it differs from the original bylaw and amending bylaws, those prevail. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.
This zone as Markdown · JSON · all Hazelton zones · Report an error