R-6 zone in Lake Cowichan: Small House Residential
In short
Small single detached dwellings on small lots at medium density in an urban setting.
Zone rules
| Purpose | Small single detached dwellings on small lots at medium density in an urban setting. |
|---|---|
| Main uses | Single detached |
| Also allowed (secondary uses) |
|
| Minimum lot area | 275 m² (single dwelling) |
| Maximum lot coverage | 60%; 50% when a secondary suite is present |
| Maximum height | 5.5 m; the ridge of pitched roofs with a minimum slope of six to twelve may extend up to 7.6 m; all parts of the roof above 5.5 m must be pitched |
| Maximum height, accessory buildings | 4.5 m for pitched roof, 3.7 m for flat roof (accessory buildings over 10 m²); 3.5 m (accessory structures under 10 m²) |
| Front setback | 1.5 m |
| Rear setback | 1.5 m |
| Interior side setback | 1.2 m |
| Street side setback | 1.5 m |
| Other rules |
|
Source: Zoning Bylaw No. 1055-2021 (consolidated as of February 24, 2026), s. Part V (read 2026-11-08)
Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.
This zone as Markdown · JSON · all Lake Cowichan zones · Report an error