# P2 zone in Merritt: Institutional and Public Use

Public use facilities, including government buildings and places of worship, and suitable locations for public utilities.

## Zone rules

- **Purpose:** Public use facilities, including government buildings and places of worship, and suitable locations for public utilities.
- **Main uses:** Bus Depot; Community Care Facility, Major; Community Care Facility, Minor; Community Care, Facility, Specialized; Daycare Centre, Major; Daycare Centre, Minor; Gallery and Museum; Place of Worship; Public Use; School, Private; School, Public
- **Also allowed (secondary uses):** Accessory Building; Assembly Place; Entertainment Facility; Participant Recreation Services, Indoor; Security / Operator Suite; School Portable; Dwelling Unit for staff, including a church manse; Urban Agriculture
- **Extra uses on specific lots:** Part of SE 1/4, Section 11, TP 91, W6M shown on the bylaw sketch plan: sand and gravel extraction is a permitted use; Lot A, DL 122, LD 25, Plan KAP47561 (Units A & B, 3191 Nicola Avenue): the Uses permitted in the R2 zone are permitted; Lot A, DL 176, Plan 34260 (319 Lindley Creek Road): a Mobile Home is permitted for a Security / Operator Suite
- **Minimum lot area:** 450 m²
- **Minimum lot width:** 15 metres
- **Maximum lot coverage:** 85% (up to 100% with permeable surfaces on at least 15% of the Parcel Area)
- **Maximum height:** Lesser of 22 metres or 5 storeys
- **Maximum height, accessory buildings:** Lesser of 5 metres or 1.5 storeys
- **Front setback:** 0 metres
- **Rear setback:** 3 metres
- **Interior side setback:** 1.2 metres
- **Street side setback:** 0 metres
- **Accessory building setbacks:** front: Front Building Line; side 1.2 metres; rear 1.2 metres
- **Other rules:** Community Care Facilities must meet the Community Care and Assisted Living Act; Minimum separation between Accessory Buildings and other Structures is 1.5 metres (3 metres for Shipping Containers from combustible Structures)