# RSE zone in District of North Vancouver: Single-Family Residential Edgemont

Development regulations unique to the Edgemont Neighbourhood.

## Zone rules

- **Purpose:** Development regulations unique to the Edgemont Neighbourhood.
- **Main uses:** One single-family residential building
- **Also allowed (secondary uses):** Home occupations; Accommodation of not more than two boarders or lodgers; Secondary suite (one per lot); Bed and breakfast business; Buildings and structures accessory to the single-family building; Coach house (one per lot; not outside the Urban Containment Boundary); Short-term rental accommodation
- **Minimum lot area:** 743.2 m² (for lots created by subdivision; from the bylaw subdivision table)
- **Minimum lot width:** 18.3 m (for lots created by subdivision; from the bylaw subdivision table)
- **Maximum lot coverage:** 35% (including parking and accessory structures)
- **Maximum density:** Floor space ratio 0.35 + 32.5 m² for all lots
- **Maximum height:** Flat roof or roof under 3 in 12: 6.1 m (20 ft); 3 in 12 or greater 7 m (23 ft); 4½ in 12 or greater 7.62 m (25 ft); 6 in 12 or greater 7.92 m (26 ft). Eave height at most 4.9 m (16 ft) at the minimum 6 ft side setback, increasing at 45 degrees to a maximum of 6.71 m (22 ft).
- **Maximum height, accessory buildings:** Other accessory buildings: flat roof 3.66 m (12 ft); roof slope 3 in 12 or greater 4.57 m (15 ft). Parking structures in required yards: flat roof 3.66 m (12 ft); roof slope 4 in 12 or greater 4.57 m (15 ft).
- **Front setback:** 7.62 m (25 ft)
- **Rear setback:** 7.62 m (25 ft)
- **Interior side setback:** 1.83 m (6 ft); combined side yards at least 20% of lot width
- **Street side setback:** 10% of lot width + 3 m (10 ft), but the building need not be less than 7.32 m (24 ft) in width
- **Accessory building setbacks:** Parking structures: from a street 6.1 m (20 ft) straight-in entry or 4.57 m (15 ft) side entry; from other detached buildings 1.52 m (5 ft); from neighbouring lot 1.22 m (4 ft) to the rear of the dwelling or 1.8 m (6 ft) elsewhere. Other accessory buildings: from a street 4.57 m (15 ft); from other buildings 1.52 m (5 ft); from neighbouring lot 1.22 m (4 ft).
- **Other rules:** Combined front and rear setback at least 18.29 m (60 ft).; Maximum building depth 19.81 m (65 ft); maximum principal building size 325.15 m² (3500 sq ft).; Paving in the required front yard limited to 40% (straight-in or no parking structure) or 60% (side-entry parking structure).; Upper storey floor area may not exceed the greater of 75% of the largest storey below or 92.9 m².

## Source

- [District of North Vancouver Zoning Bylaw, 1965 (Bylaw 3210), consolidated for convenience, document updated October 2026, s. 515](https://docs.dnv.org/documents/bylaw-3210.pdf#page=767) (read 2026-11-07)