# RSMF zone in District of North Vancouver: Single-Family Residential Murdo Frazer

Maintain the single-family residential character of properties zoned RSMF (Murdo Frazer).

## Zone rules

- **Purpose:** Maintain the single-family residential character of properties zoned RSMF (Murdo Frazer).
- **Main uses:** One single-family residential building
- **Also allowed (secondary uses):** Home occupations; Accommodation of not more than two boarders or lodgers; Secondary suite (one per lot); Bed and breakfast business; Buildings and structures accessory to the single-family building; Coach house (one per lot; not outside the Urban Containment Boundary); Short-term rental accommodation
- **Minimum lot area:** 550 m² (for lots created by subdivision; from the bylaw subdivision table)
- **Minimum lot width:** 15 m (for lots created by subdivision; from the bylaw subdivision table)
- **Maximum lot coverage:** 35% (including parking and accessory structures)
- **Maximum density:** Floor space ratio 0.45 for lots 464.5 m² or smaller; 0.35 + 32.5 m² for larger lots
- **Maximum height:** Flat roof 6.71 m (22 ft); minimum 3 in 12 pitch 7.32 m (24 ft); 4½ in 12 or greater 7.92 m (26 ft); 6 in 12 or greater 8.53 m (28 ft); maximum eave height 6.7 m (22 ft)
- **Maximum height, accessory buildings:** Flat roof 3.66 m (12 ft); roof slope 3 in 12 or greater 4.57 m (15 ft)
- **Front setback:** 7.62 m (25 ft)
- **Rear setback:** 7.62 m (25 ft)
- **Interior side setback:** 1.22 m (4 ft); combined side yards at least 20% of lot width
- **Street side setback:** 10% of lot width plus 3 m (10 ft), but the building need not be less than 7.32 m (24 ft) measured from the outside edge of the exterior walls
- **Accessory building setbacks:** Parking structures: from a street 4.57 m (15 ft) straight-in entry or 3.0 m (10 ft) side entry; from a lane or other building 1.52 m (5 ft); from neighbouring lot 1.2 m (4 ft). Other accessory buildings: from a street 3.0 m (10 ft); from a lane or other building 1.52 m (5 ft); from neighbouring lot 1.2 m (4 ft).
- **Other rules:** Combined front and rear setback at least 18.29 m (60 ft).; Maximum building depth 19.81 m (65 ft).; Maximum principal building size 280 m² (3,013 sq ft).; Covered entry height at most 3.66 m (12 ft) with a flat roof or 4.3 m (14 ft) with a roof of 3 in 12 or greater.

## Source

- [District of North Vancouver Zoning Bylaw, 1965 (Bylaw 3210), consolidated for convenience, document updated October 2026, s. 507](https://docs.dnv.org/documents/bylaw-3210.pdf#page=725) (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply. All zones in District of North Vancouver: https://govhandbook.com/ca/bc/north-vancouver-district/zoning/index.json