# RSQ zone in District of North Vancouver: Single-Family Residential Queensdale

Development regulations unique to the Queensdale Neighbourhood.

## Zone rules

- **Purpose:** Development regulations unique to the Queensdale Neighbourhood.
- **Main uses:** One single-family residential building
- **Also allowed (secondary uses):** Home occupations; Accommodation of not more than two boarders or lodgers; Secondary suite (one per lot); Bed and breakfast business; Buildings and structures accessory to the single-family building; Coach house (one per lot; not outside the Urban Containment Boundary); Short-term rental accommodation
- **Minimum lot area:** As illustrated on the Queensdale Zone map (for lots created by subdivision; from the bylaw subdivision table)
- **Minimum lot width:** As illustrated on the Queensdale Zone map (for lots created by subdivision; from the bylaw subdivision table)
- **Maximum lot coverage:** 40% (including parking and accessory structures)
- **Maximum density:** Floor space ratio: the greater of .45 or 2,200 sq ft, for all lots
- **Maximum height:** Lots under 12.19 m (40 ft) wide: flat roof 6.71 m (22 ft); 3 in 12 or greater 7.92 m (26 ft); 4½ in 12 or greater 8.53 m (28 ft). Lots 12.19 m (40 ft) or wider: flat roof 6.71 m; 3 in 12 or greater 7.92 m; 4½ in 12 or greater 8.53 m; 6 in 12 or greater 9.14 m (30 ft); 9 in 12 or greater 9.75 m (32 ft). Maximum eave height 6.71 m (22 ft).
- **Maximum height, accessory buildings:** Flat roof 3.66 m (12 ft); roof slope 3 in 12 or greater 4.57 m (15 ft)
- **Front setback:** 7.62 m (25 ft)
- **Rear setback:** 7.62 m (25 ft)
- **Interior side setback:** 1.22 m (4 ft); combined side yards at least 20% of lot width
- **Street side setback:** 10% of lot width, but the building need not be less than 7.32 m (24 ft) in width
- **Accessory building setbacks:** Parking structures: from a street 4.5 m (15 ft) straight-in entry or 3.0 m (10 ft) side entry; from a lane or other building 1.52 m (5 ft); from neighbouring lot 1.2 m (4 ft). Other accessory buildings: from a street 3.0 m (10 ft); from a lane or other building 1.52 m (5 ft); from neighbouring lot 1.2 m (4 ft).
- **Other rules:** Maximum building depth 19.81 m (65 ft).; Maximum principal building size 551.83 sq m (5,940 sq ft).; Parking structure in a required front yard: no more than the lesser of 25% of the required front yard or 53.5 sq m (576 sq ft).