GovHandbook

RM-2 zone in North Vancouver: Medium Density Apartment Residential 2

North Vancouver, British ColumbiaDraft, not yet reviewedBylaw read 2026-11-07

In short

To permit a range of mid-density housing types including Townhouses and Apartments in areas designated Residential Level 5 in the Official Community Plan, with densities up to 1.6 FSR

Zone rules

PurposeTo permit a range of mid-density housing types including Townhouses and Apartments in areas designated Residential Level 5 in the Official Community Plan, with densities up to 1.6 FSR
Main uses
  • One-Unit Residential Use
  • Two-Unit Residential Use
  • Townhouse Residential Use
  • Apartment Residential Use
  • Rental Apartment Residential Use
  • Child Care Use
  • Residential Care Facility Use
The bylaw lists these in a use figure and says the zone allows the uses indicated by the shaded area; the shading is not readable in the text.
Also allowed (secondary uses)
  • Accessory Secondary Suite Use
  • Accessory Coach House Use
  • Accessory Bed and Breakfast Use
  • Accessory Hen Keeping
  • Accessory Boarding Use
  • Accessory Dwelling Unit Use
  • Accessory Lock-Off Unit Use
  • Accessory Home Occupation Use
  • Accessory Home Office Use
  • Accessory Off-Street Parking Use
  • Accessory Off-Street Loading Use
The bylaw lists these in a use figure and says the zone allows the uses indicated by the shaded area; the shading is not readable in the text.
Minimum lot areaTownhouse use: 360 m² (lots existing before Bylaw 8464) or 540 m² (other lots); Apartment Residential Use: 650 m²
Minimum lot width10 m front lot line length for townhouse, one-unit and two-unit residential use; 18 m for apartment residential use
Maximum lot coverage60%
Maximum densityTotal gross floor area up to 1.6 times the lot area
Maximum heightBuilding envelope of 15 m from average building grades. For apartment, rental apartment and residential care facility use it is measured from the street for the first 28 m of lot depth and from the lane for the rest; for other uses, from the street for the front half of the lot and from the lane for the rest
Maximum height, accessory buildingsAccessory buildings: 3.658 m from building grades at the rear lot line (4.57 m where the roof slope exceeds a 4 in 12 pitch)
Front setback3 m (1.9 m on lots fronting East 3rd Street between St. David's Avenue and Ridgeway Avenue)
Rear setback1.6 m
Interior side setback2.4 m
Street side setback2.4 m
Accessory building setbacksAccessory buildings: rear 1.22 m, exterior side 3.048 m, interior side 0.61 m, and 3.048 m from the principal building
Other rules
  • Each dwelling unit must have a gross floor area of at least 37.2 m²
  • Townhouse developments with ten or more principal dwelling units must provide lock-off units: at least one for every five principal units over 140 m² gross floor area

Source: Zoning Bylaw, 1995, No. 6700, Divisions I-VII (consolidated for convenience, March 2, 2026), s. 572 (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. Consolidated for convenience only. Zones are grouped by topic in Parts 5 to 8, so most general zones share a Part-wide line range; each Comprehensive Development zone has its own range. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.

This zone as Markdown · JSON · all North Vancouver zones · Report an error