{"title":"IN1 zone in Sechelt: Institutional One Zone","code":"IN1","slug":"in1","name":"Institutional One Zone","group":"Public","section":"1.26","site_specific_zone":false,"summary":"A community care facility for long term care, licensed and operated under the Community Care and Assisted Living Act, the Residential Care Regulation, and the Home and Community Care Policy Manual.","fields":{"purpose":{"value":"A community care facility for long term care, licensed and operated under the Community Care and Assisted Living Act, the Residential Care Regulation, and the Home and Community Care Policy Manual.","quotes":["To provide for a community care facility for long term care that is licensed and operated in","accordance with the Community Care and Assisted Living Act, the Residential Care Regulation,"]},"primary_uses":{"value":["Community Care Facility"],"quotes":["Community Care Facility Outdoor Recreation"]},"secondary_uses":{"value":["Outdoor Recreation"],"quotes":["Community Care Facility Outdoor Recreation"]},"min_parcel_area":{"value":"1.2 ha","quotes":["Minimum Lot Area 1.2 ha"]},"min_parcel_width":{"value":"144 m (minimum lot depth 84 m)","quotes":["Minimum Lot Width 144 m","Minimum Lot Depth 84 m"]},"max_parcel_coverage":{"value":"40% for all buildings and structures; 45% for impervious surfaces","quotes":["All buildings and structures shall not cover more than 40% of the Lot Area","Impervious surfaces shall not cover more than 45% of the Lot Area"]},"max_density":{"value":"Maximum Gross Floor Area 8,500 m2; maximum footprint 4,000 m2; maximum Floor Area Ratio 0.71","quotes":["Maximum Gross Floor Area 8,500 m2","Maximum Footprint 4,000 m2","Maximum Floor Area Ratio 0.71 FAR"]},"max_height":{"value":"13.0 m (Community Care Facility); 8.0 m (Hospice Facility)","quotes":["Community Care Facility 13.0 m","Hospice Facility 8.0 m"]},"max_height_accessory":{"value":"5.0 m","quotes":["Accessory Structure 5.0 m"]},"setback_front":{"value":"18.0 m","quotes":["Principal Use 18.0 m 6.0 m 6.0 m 6.0 m"]},"setback_rear":{"value":"6.0 m","quotes":["Principal Use 18.0 m 6.0 m 6.0 m 6.0 m"]},"setback_side_interior":{"value":"6.0 m","quotes":["Principal Use 18.0 m 6.0 m 6.0 m 6.0 m"]},"setback_side_exterior":{"value":"6.0 m","quotes":["Principal Use 18.0 m 6.0 m 6.0 m 6.0 m"]},"accessory_setbacks":{"value":"Accessory structures: front 1.5 m, rear 1.5 m, interior side 1.5 m, exterior side 1.5 m","quotes":["Accessory","1.5 m 1.5 m 1.5 m 1.5 m"]},"other":{"value":["Landscaped buffer at least 3.0 m wide at the front (south) and 4.0 m wide at the side (west), with plantings at least 2.0 m high","A Porte Cochere may project to within 10 m of the property line"],"quotes":["The minimum width of the front (south)","3.0 m","The minimum width of the side (west)","4.0 m","The minimum Height of landscaped buffer area","2.0 m","a) A Porte Cochere projecting from the Principal Building may be located to within 10 m of the"]}},"bylaw":{"title":"Zoning Bylaw No. 580, 2022 (consolidated for convenience, May 2025, to Bylaw 580-17, 2024)","url":"https://www.sechelt.ca/media/rdjpiexj/580-2022-zoning-bylaw.pdf","accessed":"2026-11-07","note":"The District's consolidation is for convenience only and is not admissible in court unless certified by the Corporate Officer; the original bylaws prevail. Amendments adopted after May 2025 are not in this text."},"source_url":"https://www.sechelt.ca/media/rdjpiexj/580-2022-zoning-bylaw.pdf#page=61","place":{"path":"ca/bc/sechelt","name":"Sechelt","region":{"code":"bc","name":"British Columbia"},"country":{"code":"ca","name":"Canada"}},"urls":{"html":"https://govhandbook.com/ca/bc/sechelt/zoning/in1/","markdown":"https://govhandbook.com/ca/bc/sechelt/zoning/in1.md","json":"https://govhandbook.com/ca/bc/sechelt/zoning/in1.json","index":"https://govhandbook.com/ca/bc/sechelt/zoning/index.json"}}