{"title":"PC zone in Surrey: Cemetery Zone","code":"PC","slug":"pc","name":"Cemetery Zone","group":"Public","section":"Part 30","site_specific_zone":false,"summary":"Cemeteries and related uses.","fields":{"purpose":{"value":"Cemeteries and related uses.","quotes":["This Zone is intended to accommodate cemeteries and related uses, subject to the Cemetery and"]},"primary_uses":{"value":["Cemetery including crematories, columbarium, mausoleums and mortuaries","General service uses limited to funeral parlour and memorial service facility (not the only use on the lot)","Pet cemetery including pet crematories"],"quotes":["1. Cemetery including crematories, columbarium, mausoleums and mortuaries; subject to","(a) Funeral parlour; and","(b) Memorial service facility, provided that such facility does not constitute a singular","3. Pet cemetery including pet crematories."]},"secondary_uses":{"value":["Caretaker unit (accommodation for an official, manager or caretaker of the principal uses)"],"quotes":["4. Caretaker unit, which in this Zone, includes accommodation for an official, manager or"]},"min_parcel_area":{"value":"2,000 m²","quotes":["1. Lot Area: Minimum 2,000 sq. m."]},"min_parcel_width":{"value":"30 m","quotes":["2. Lot Width: Minimum 30 m."]},"max_parcel_coverage":{"value":"20% (burial plots excluded)","quotes":["The maximum lot coverage for all buildings and structures shall be 20%; excludes burial plots."]},"max_density":{"value":"Floor area ratio 0.20","quotes":["The maximum density for all buildings and structures shall not exceed a floor area ratio of 0.20."]},"max_height":{"value":"14.0 m","quotes":["Principal building height shall not exceed 14.0 m."]},"max_height_accessory":{"value":"4 m (5 m if roof slope and materials match the principal building); structures 5.0 m","quotes":["(a) Accessory building height shall not exceed 4 m; and","(b) Accessory building height may be increased to 5 m where the roof slope and","Structure height shall not exceed 5.0 m."]},"setback_front":{"value":"7.5 m from all lot lines except internal lot lines","quotes":["Buildings and structures shall be sited not less than 7.5 m from all lot lines excepting internal lot"]},"setback_rear":{"value":"7.5 m from all lot lines except internal lot lines","quotes":["Buildings and structures shall be sited not less than 7.5 m from all lot lines excepting internal lot"]},"setback_side_interior":{"value":"7.5 m from all lot lines except internal lot lines","quotes":["Buildings and structures shall be sited not less than 7.5 m from all lot lines excepting internal lot"]},"setback_side_exterior":{"value":"7.5 m from all lot lines except internal lot lines","quotes":["Buildings and structures shall be sited not less than 7.5 m from all lot lines excepting internal lot"]},"other":{"value":["Minimum lot depth is 2 times the lot width.","A pet cemetery and a human cemetery on the same operation must be separated by a landscape buffer at least 10 m wide."],"quotes":["3. Lot Depth: Minimum 2 times lot width.","these two uses shall be separated by a minimum 10 m wide landscape buffer"]}},"bylaw":{"title":"Surrey Zoning By-law, 1993, No. 12000 (consolidation includes amendments up to By-law 22120, adopted 09/21/2026)","url":"https://www.surrey.ca/sites/default/files/bylaws/BYL_Zoning_12000.pdf","accessed":"2026-11-07","note":"Each Comprehensive Development (CD) zone is a separate site-specific by-law attached to Part 52 (listed on the Surrey map by lot as \"CD\" with its by-law number); those by-laws are not written out in this PDF."},"source_url":"https://www.surrey.ca/sites/default/files/bylaws/BYL_Zoning_12000.pdf#page=261","place":{"path":"ca/bc/surrey","name":"Surrey","region":{"code":"bc","name":"British Columbia"},"country":{"code":"ca","name":"Canada"}},"urls":{"html":"https://govhandbook.com/ca/bc/surrey/zoning/pc/","markdown":"https://govhandbook.com/ca/bc/surrey/zoning/pc.md","json":"https://govhandbook.com/ca/bc/surrey/zoning/pc.json","index":"https://govhandbook.com/ca/bc/surrey/zoning/index.json"}}