R12 zone in Coldstream: Townhouse Zone
Accommodate 8 or more Dwelling Units in a multi-family residential development.
Zone rules
| Purpose | Accommodate 8 or more Dwelling Units in a multi-family residential development. |
|---|---|
| Main uses |
|
| Also allowed (secondary uses) |
|
| Minimum lot area | 4,050 m² |
| Minimum lot width | Corner lot 30 m; interior lot 24 m |
| Maximum lot coverage | 60% for all buildings and structures; 15% for impervious hard-surfaced areas |
| Maximum density | Minimum 8 strata lots (no maximum stated) |
| Maximum height | 11 m or 3 storeys |
| Maximum height, accessory buildings | 4.5 m |
| Front setback | 6 m; 4 m if abutting a sidewalk |
| Rear setback | 6 m (principal building) |
| Interior side setback | 3 m |
| Street side setback | 4 m |
| Accessory building setbacks | rear 3 m (accessory buildings and structures) |
| Other rules |
|
Source: Zoning Bylaw No. 1838, 2024 (consolidated for convenience, includes amendments adopted up to June 8, 2026), s. 512 (read 2026-11-07)
Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. The District marks the consolidation "for convenience only". The zones are in Schedule A (the url above); the cover and enacting bylaw are at http://coldstream.civicweb.net/Documents/DocumentDisplay.aspx?Id=56951 and the zoning map is Schedule B. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.
This zone as Markdown · JSON · all Coldstream zones · Report an error