GovHandbook

RM-1 zone in Coquitlam: Two-Storey Low Density Apartment Residential

Coquitlam, British ColumbiaDraft, not yet reviewedBylaw read 2026-11-07

In short

Two-storey apartment and townhouse developments at a low density.

Zone rules

PurposeTwo-storey apartment and townhouse developments at a low density.
Main uses
  • Apartment
  • Townhouse
  • Congregate Housing and Care
Also allowed (secondary uses)
  • Boarding
  • Accessory residential
  • Accessory home occupation
  • Retail of goods made in resident workshops and goods and services to residents (Congregate Housing and Care buildings only)
  • Workshops for residents, social and recreation space and facilities
  • Assembly child care
  • Accessory institutional support services
Minimum lot area1,110 m² (apartment or townhouses); 555 m² (boarding)
Maximum lot coverage30% for all uses combined
Maximum densityGross floor area up to 0.45 times the lot area for apartment or townhouse use; each dwelling unit needs at least 220 m² of lot area
Maximum heightTwo storeys (the floor below the first storey may be exposed on one side of a building on a sloping lot)
Front setback7.6 m (lot lines along a street or lane)
Rear setbackRear lot line not along a street or lane: 50% of the building height up to 9 m plus 30% of the height above 9 m, but not less than 3.0 m (wall with no window or window to a non-habitable room) or 7.6 m (wall with a balcony or window to a habitable room)
Interior side setback50% of the building height up to 9 m plus 30% of the height above 9 m, but not less than 3.0 m (wall with no window or window to a non-habitable room) or 7.6 m (wall with a balcony or window to a habitable room)
Street side setback7.6 m (lot lines along a street or lane)
Accessory building setbacksAttached to or less than 1.6 m from a residential building: same as principal buildings. Detached 1.6 m or more away: front 7.6 m, rear 1.2 m, interior side 1.2 m, exterior side 3.8 m
Other rules
  • Townhouse buildings at most 55 m long; apartment buildings at most 65 m long (architectural breaks where over 37 m)
  • Studio units may not exceed 30% of the dwelling units in a building
  • Each dwelling needs access to at least 5.0 m² of common amenity area
  • Maximum lot size for a public park is 0.8 hectares

Source: Zoning Bylaw No. 3000, 1996 (consolidated with amending bylaws, updated July 27, 2026), s. 1201 (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. The City says this consolidated copy is for convenience only and is not an official copy. It is published as separate PDFs per part (Parts 1-22); no zone parts exist for 9, 11 and 14. Schedule A (zoning maps) points to QtheMap. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.

This zone as Markdown · JSON · all Coquitlam zones · Report an error