GovHandbook

RU6 zone in Lake Country: Large Lot Small-Scale Multiple Housing

Lake Country, British ColumbiaDraft, not yet reviewedBylaw read 2026-11-07

In short

A zone that permits up to four dwelling units with compatible secondary uses on larger serviced urban lots.

Zone rules

PurposeA zone that permits up to four dwelling units with compatible secondary uses on larger serviced urban lots.
Main uses
  • Group homes, minor
  • Two dwelling housing
  • Small-scale multiple housing
Also allowed (secondary uses)
  • Home occupations
  • Utility services, minor impact
  • Secondary suite
  • Accessory suite
Secondary and accessory suites are only permitted on lots where small-scale multiple housing is a permitted use.
Minimum lot area700 m² (800 m² for a corner lot)
Minimum lot width18.0 m (20.0 m for a corner lot)
Maximum lot coverageTwo dwelling housing and group home, minor: 40% (50% with driveways and parking areas); small-scale multiple housing: 50% (60% with driveways and parking areas)
Maximum densityUp to four dwelling units; a maximum of two secondary suites, two accessory suites, or one of each per lot
Maximum heightTwo dwelling housing and group home, minor: lesser of 9.5 m or 2½ storeys; small-scale multiple housing: lesser of 11 m or 3 storeys
Maximum height, accessory buildings4.5 m (lesser of 8m or 2 storeys for an accessory building containing an accessory suite)
Front setbackTwo dwelling housing: 4.5 m; small-scale multiple housing: 4 m; 6.0 m to a garage door or carport entrance with vehicular entry from the front
Rear setbackTwo dwelling housing: 6.0 m (4.5 m where lot width exceeds lot depth, if one side yard is at least 4.5 m); small-scale multiple housing: 3 m; accessory buildings: 1.5 m
Interior side setbackTwo dwelling housing: 2.0 m; small-scale multiple housing: 1.5 m
Street side setbackTwo dwelling housing: 3.0 m from a flanking street; small-scale multiple housing: 4.0 m; 6.0 m from a flanking street to a garage door or carport entrance accessed from that street
Accessory building setbacksrear 1.5 m (3 m for an accessory building containing an accessory suite)
Other rules
  • Small-scale multiple housing is only permitted on lots inside the urban containment boundary, connected to municipal sewer and water, and 4,050 m² or smaller.
  • Minimum setback between principal buildings (small-scale multiple housing): 3m.
  • Where there is rear lane access, vehicle access is only from the lane (unless slope over 15%).
  • Small-scale multiple housing needs at least 7.5 m² of private open space per dwelling unit.

Source: Zoning Bylaw 561, 2007 (consolidated 2026-08-18; cover page says it includes amendments as of June 2, 2026), s. 15.4 (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. A consolidated copy to be used for convenience only; users are asked to refer to the Zoning Bylaw as amended from time to time to verify accuracy and completeness. The bylaw's own zone table also lists DC6 (Direct Control 6), but that section is marked deleted by Bylaw 719 and is not listed below. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.

This zone as Markdown · JSON · all Lake Country zones · Report an error