GovHandbook

MR5 zone in Surrey: Stacked Townhouse Zone

Surrey, British ColumbiaDraft, not yet reviewedBylaw read 2026-11-07

In short

Stacked townhouses, typically 3 to 4 storeys, developed under a comprehensive design.

Zone rules

PurposeStacked townhouses, typically 3 to 4 storeys, developed under a comprehensive design.
Main uses
  • Stacked townhouse buildings
  • Ground-oriented multiple unit residential buildings
  • Ground-oriented back-to-back multiple unit residential buildings
Also allowed (secondary uses)
  • Child care centres
  • Short-Term Rental
Minimum lot area1,000 m²
Minimum lot width36 m
Maximum lot coverage50%
Maximum densityFloor area ratio 1.5
Maximum heightLesser of 4 storeys or 14 m
Maximum height, accessory buildings4.5 m (accessory buildings and structures)
Front setback4.5 m (2.5 m for a covered porch or veranda)
Rear setback6.0 m (4.0 m for a deck or balcony on the main and second floor)
Interior side setback6.0 m (4.0 m for a deck or balcony on the main and second floor)
Street side setback4.5 m (2.5 m for a covered porch or veranda)
Other rules
  • Balconies are required on dwelling units that are not ground-oriented.
  • Back-to-back ground-oriented units are limited to 20% of all dwelling units where there is no underground parking.

Source: Surrey Zoning By-law, 1993, No. 12000 (consolidation includes amendments up to By-law 22120, adopted 09/21/2026), s. Part 22A (read 2026-11-07)

Rules in the bylaw's general sections (parking, fences, suites, home businesses) also apply, and a lot can have site-specific rules. Each Comprehensive Development (CD) zone is a separate site-specific by-law attached to Part 52 (listed on the Surrey map by lot as "CD" with its by-law number); those by-laws are not written out in this PDF. Zone pages are taken from the bylaw text by a research agent and have not yet been reviewed by a person: confirm with the bylaw before you rely on them. How answers are checked.

This zone as Markdown · JSON · all Surrey zones · Report an error